Slide-out repair checks
| Check |
Action |
Stop |
| Battery |
Confirm the battery is fully charged and connected. |
Stop if voltage is low. |
| Arm timing |
Confirm drive and follow arms are timed. |
Stop if the room travels unevenly. |
| Room adjustment |
Loosen the carriage bolts, adjust the room, and tighten before operating. |
Stop if the room will not stay adjusted. |
| Stop blocks |
Loosen the set screw, set the in/out stop, and tighten. |
Stop if the stop block is damaged. |
| Manual override |
Crank the room in, check the seal, engage the brake, and reconnect the motor leads. |
Stop if the motor or brake is damaged. |
| Motor |
Do not disassemble the motor; replace it if it fails. |
Stop if the motor is failed. |
Slide-out seal checks
| Check |
Action |
Stop |
| Room adjustment |
Adjust the room vertically and tighten the carriage bolts. |
Stop if the room will not adjust. |
| Stop block |
Set the in/out stop so the room seats correctly. |
Stop if the room over-travels. |
| Seal |
Crank the room in with the override and check for a good seal. |
Stop if the seal is torn or water enters. |
Source: Lippert Above Floor Slide-out Manual CCD-0009283