RV Converter Diagnose, Replace, and Install

Converter diagnose checks

Check Action Stop
Reverse fuses Check the reverse polarity fuses first. Stop and reconnect the battery if a fuse is blown.
Output voltage Disconnect battery cables, confirm 105-132 V AC, and measure 13.6 Vdc +/-0.2 at the cables. Stop if the reading is 0 V.
0 V path Check the inline fuse, battery wire, ground, and torque. Stop if the converter fuses and AC are good but output is still 0 V.
Mode cycling If it cycles between absorption and bulk, suspect a shorted battery cell. Stop and test the battery.

Converter replacement checks

Check Action Stop
Serviceability Do not open or repair the converter; it has no serviceable parts. Stop and replace.
Fuse Use the same type and amp rating for a reverse polarity fuse. Stop if the rating is unknown.
Breaker Use the same manufacturer/type and equal or greater interrupting rating, not over 30 A. Stop if the breaker does not match.
Technician Use an experienced technician. Stop if AC/DC work is not qualified.

Converter installation checks

Check Requirement Stop
Technician Installation must be by an experienced technician. Stop if not qualified.
Compartment Do not install in a battery, flammable, or LP compartment; do not block ventilation. Stop if the location is not ventilated and non-LP.
Breaker Match manufacturer/type and rating, not over 30 A. Stop if the breaker does not match.
Polarity Connect the battery correctly; reverse connection blows the reverse polarity fuses. Stop if polarity is unknown.
Battery fluid Check battery fluid monthly. Stop if the battery is not accessible.

Source: WFCO WF-8900 Series Operator Manual