Converter diagnose checks
| Check |
Action |
Stop |
| Reverse fuses |
Check the reverse polarity fuses first. |
Stop and reconnect the battery if a fuse is blown. |
| Output voltage |
Disconnect battery cables, confirm 105-132 V AC, and measure 13.6 Vdc +/-0.2 at the cables. |
Stop if the reading is 0 V. |
| 0 V path |
Check the inline fuse, battery wire, ground, and torque. |
Stop if the converter fuses and AC are good but output is still 0 V. |
| Mode cycling |
If it cycles between absorption and bulk, suspect a shorted battery cell. |
Stop and test the battery. |
Converter replacement checks
| Check |
Action |
Stop |
| Serviceability |
Do not open or repair the converter; it has no serviceable parts. |
Stop and replace. |
| Fuse |
Use the same type and amp rating for a reverse polarity fuse. |
Stop if the rating is unknown. |
| Breaker |
Use the same manufacturer/type and equal or greater interrupting rating, not over 30 A. |
Stop if the breaker does not match. |
| Technician |
Use an experienced technician. |
Stop if AC/DC work is not qualified. |
Converter installation checks
| Check |
Requirement |
Stop |
| Technician |
Installation must be by an experienced technician. |
Stop if not qualified. |
| Compartment |
Do not install in a battery, flammable, or LP compartment; do not block ventilation. |
Stop if the location is not ventilated and non-LP. |
| Breaker |
Match manufacturer/type and rating, not over 30 A. |
Stop if the breaker does not match. |
| Polarity |
Connect the battery correctly; reverse connection blows the reverse polarity fuses. |
Stop if polarity is unknown. |
| Battery fluid |
Check battery fluid monthly. |
Stop if the battery is not accessible. |
Source: WFCO WF-8900 Series Operator Manual