Solar setup checks
| Check |
Requirement |
Stop |
| Device limits |
Check controller/inverter PV maximum power, voltage range, and current. |
Stop if the limits are unknown. |
| Panel match |
Use panels of the same specification and batch. |
Stop if brands, ratings, or ages are mixed. |
| Series/parallel |
Series adds voltage; parallel adds current; power adds in both. |
Stop if total Voc or current exceeds the device. |
Solar install checks
| Check |
Requirement |
Stop |
| Tilt |
Flat mounting for travel; local latitude tilt only for long-term stationary camping. |
Stop if the mount cannot be secured for travel. |
| Rigid mount |
Use pre-drilled M6/M8 holes; torque M6 8-10 Nm or M8 12-15 Nm; keep a 10 cm ventilation gap. |
Stop if torque or gap cannot be met. |
| Flexible panel |
Bend no more than 30 degrees and use at least 6 adhesive contact lines. |
Stop if the surface cannot meet that bend. |
| Cleaning |
Use water and mild dish soap; no pressure washer, acid, or alkaline cleaner. |
Stop if the glass is broken. |
| Inspection |
Every 6 months check glass, backsheet, frame, connectors, Voc/Isc, and bolt torque. |
Stop if Voc/Isc is outside 5% of nominal. |
Source: Renogy Solar Panel Installation & Maintenance Manual
Related RV owner guides