RV Slide Out Repair and Seal Check

Slide-out repair checks

Check Action Stop
Battery Confirm the battery is fully charged and connected. Stop if voltage is low.
Arm timing Confirm drive and follow arms are timed. Stop if the room travels unevenly.
Room adjustment Loosen the carriage bolts, adjust the room, and tighten before operating. Stop if the room will not stay adjusted.
Stop blocks Loosen the set screw, set the in/out stop, and tighten. Stop if the stop block is damaged.
Manual override Crank the room in, check the seal, engage the brake, and reconnect the motor leads. Stop if the motor or brake is damaged.
Motor Do not disassemble the motor; replace it if it fails. Stop if the motor is failed.

Slide-out seal checks

Check Action Stop
Room adjustment Adjust the room vertically and tighten the carriage bolts. Stop if the room will not adjust.
Stop block Set the in/out stop so the room seats correctly. Stop if the room over-travels.
Seal Crank the room in with the override and check for a good seal. Stop if the seal is torn or water enters.

Source: Lippert Above Floor Slide-out Manual CCD-0009283

Related RV owner guides